0 hex Word Growatt ??00=standby, 01??=AC output disable 1 hex Word AC Output first prioroty 0=Bat 1=PV 2=Uti 3=PV&Uti 2 hex Word Charge Source set 0:PV_first 1:PV&Uti 2:PV_Only 3 hex Word Uti Output Start time (0-23)= 0 4 hex Word Uti Output End Timer (0-23)= 0 5 hex Word Uti Charge Start Time (0-23)= 0 6 hex Word Uti Charge End Time (0-23)= 0 7 hex Word PV Input Mode W 0:Independent 1:Parallel= 0 8 hex Word AC Input Mode VAC 0:APL_90-140 1:UPS_65-140 2:Generator 9 hex Word Firmware version High 10 hex Word Firmware version Mid 11 hex Word Firmware version Low 12 hex Word Control Firmware version High 13 hex Word Control Firmware version Mid 14 hex Word Control Firmware version Low 15 hex Word LCD Language 16 hex Word GridV_Adj 17 hex Word InvV_Adj 18 hex Word OutputVoltType 6:120VAC 19 hex Word OutputFreqType 1:60 Hz 20 hex Word OverLoadRestart 0:Yes 1:No 2:Switch to Uti. Was 0001 21 hex Word OverTemperatureRestart 0:Yes 1:No. Was 0001 22 hex Word Buzzer 1:Enable 0:Disable 23 hex Word Serial No. 5 24 hex Word Serial No. 4 25 hex Word Serial No. 3 26 hex Word Serial No. 2 27 hex Word Serial No. 1 28 hex Word Inverter Module high 29 hex Word Inverter Module low